Working on roofs in Germany: planning and inspecting fall protection on buildings
Servicing the ventilation system, cleaning the roof drains, installing a photovoltaic system: work is carried out on roofs more often than many operators think. From what height protection is required, which solution takes priority, what applies to rooflights and anchor points and who is responsible for inspection.
Last updated on 9 min readAMS Go editorial team
Key points at a glance
- A fall hazard exists at a fall height of more than 1.0 m. Workplaces and traffic routes more than 2.0 m from the fall edge are outside the danger zone; the zone must be secured against unauthorised access and marked (ASR A2.1 nos. 4.1 and 5.4).
- In construction work, fall protection is required at workplaces from a fall height of more than 2.00 m and at traffic routes, exposed stairs and wall openings from more than 1.00 m; for small, flat roofs up to 50 m² there is a narrowly defined exception up to 3.00 m (ASR A2.1 no. 8.2, Section 9 DGUV Vorschrift 38).
- The order of priority applies: fall prevention such as guard rails before fall arrest installations such as catch scaffolds and safety nets, and only then personal fall protection equipment (ASR A2.1 no. 4.2).
- Dome rooflights, continuous rooflights, corrugated sheets and photovoltaic elements may not be safe to walk on; access points to such roofs must be kept locked, and safe traffic routes are needed (ASR A2.1 nos. 3.11 and 7.1).
- Anchor devices are a prerequisite for personal fall protection equipment. The operator is responsible for their functional safety; DGUV Information 201-056 recommends inspection at intervals of no more than 12 months.
From when protection is required on the roof
It is not only roofers who work on roofs. The workplace rule ASR A2.1 “Schutz vor Absturz und herabfallenden Gegenständen, Betreten von Gefahrenbereichen” (protection against falls and falling objects, entering danger zones) gives as examples inspections and maintenance of technical equipment, filter changes on ventilation systems, reading measuring instruments, care of green roofs, cleaning drains, clearing snow and the maintenance of rooflights, smoke and heat exhaust systems and photovoltaic systems (no. 7 (1)). For all this work the employer must determine whether there is a fall hazard. The ASR was last amended in March 2022, mainly with regard to the requirements for construction sites in no. 8.
Workplace in general: fall hazard
Thresholdfall height of more than 1.0 m
BasisASR A2.1 no. 4.1 (4)
Workplaces and traffic routes 0.2 m to 1.0 m above the adjacent surface, risk of slipping off or sinking in
Thresholdprotective measures according to the risk assessment
BasisASR A2.1 no. 4.1 (3)
Construction site: workplaces and traffic routes at or above water or substances in which a person can sink
Thresholdregardless of fall height
BasisASR A2.1 no. 8.2 (7), Section 9 (2) DGUV Vorschrift 38
Construction site: exposed flights of stairs and landings, wall openings, traffic routes
Thresholdfall height of more than 1.00 m
BasisASR A2.1 no. 8.2 (7), Section 9 (2) DGUV Vorschrift 38
Construction site: all other workplaces
Thresholdfall height of more than 2.00 m
BasisASR A2.1 no. 8.2 (7), Section 9 (2) DGUV Vorschrift 38
Construction site: roofs and floor slabs with a pitch of up to 22.5° and a floor area of no more than 50 m²
Thresholdprotective device dispensable up to a fall height of 3.00 m if the work is done by professionally qualified, physically fit and specially instructed employees and the fall edge is clearly recognisable
BasisASR A2.1 no. 8.2 (7), Section 9 (2) DGUV Vorschrift 38
Order of priority on the roof: guard rail before net before harness
Structural and technical measures take priority over organisational and individual ones. The basics of the order of priority and everything about the personal protective equipment itself are explained in the guide “Fall protection equipment”. For the roof, the order of priority means specifically:
Level 1. Fall prevention (Absturzsicherung)
Solutions on the roofGuarding such as guard rails or a sufficiently high parapet, edge protection, covering of openings
Key requirementsGuarding at least 1.00 m high, at least 1.10 m at a fall height of more than 12 m; on construction sites at least 1.00 m, 950 mm for system components, with a toe board of at least 0.15 m (ASR A2.1 nos. 5.1 and 8.2)
Level 2. Fall arrest installation (Auffangeinrichtung)
Solutions on the roofRoof catch scaffold, protective wall, safety net
Key requirementsOn construction sites, a fall height of up to 2.00 m into catch scaffolds and working platform nets and up to 3.00 m into safety nets is permissible (ASR A2.1 no. 8.2 (9))
Level 3. Personal fall protection equipment
Solutions on the roofRestraint or fall arrest system on a cable system, rail system or single anchor points
Key requirementsOnly if fall prevention and fall arrest installations cannot be set up; suitable anchor devices, instruction and rescue measures are prerequisites (ASR A2.1 no. 4.2)
For planning, DGUV Information 201-056 “Schutzmaßnahmen gegen Absturz auf Dächern” (protective measures against falls on roofs) offers an assessment procedure: depending on how often and by whom a roof is accessed, an equipment class results. Class A stands for collective protection by guarding and edge protection, class B for permanent cable and rail systems that can be traversed without unhooking, class C for single anchor devices and cable systems that cannot be traversed. The more often a roof is walked on and the less practised the persons are, the more class A is called for.
Fragile roof surfaces and rooflights
Breaking through a surface that is not load-bearing also counts as a fall (ASR A2.1 no. 3.1). Components are safe to walk on (durchtrittsicher) if they do not break when stepped on and employees cannot fall through them. Components that may not be safe to walk on include, for example, fibre cement, asbestos cement and bitumen corrugated sheets, rooflights such as translucent sheets, continuous rooflights and dome rooflights, glass and plastic roofs, glazing and solar or photovoltaic elements (no. 3.11). The transition from a surface that is safe to walk on to one that is not is a fall edge (no. 3.2).
- Access points to roofs that are not safe to walk on, such as roof exits and hatches, must be kept locked. Only specially instructed and authorised persons may open them (ASR A2.1 no. 7.1 (1)).
- Permanent and clearly visible marking must be affixed at the access points, for example “Use roof only on walkways”.
- If such roofs have to be walked on, safe traffic routes to the work area are needed, for example walkways that withstand the loads, are at least 0.50 m wide and are guarded on both sides. One side is sufficient if guarding on both sides would obstruct the work and anchor devices for personal fall protection equipment are available (no. 7.1 (2)).
- Dome rooflights and continuous rooflights that are not safe to walk on by design must be fitted with guarding, covers or nets or grids underneath that prevent anyone falling through (no. 7.1 (3)).
- In existing buildings, for work and traffic routes within 2.0 m of such rooflights it must be ensured that barriers or covers prevent a fall.
- This can be dispensed with if the upstand of the component that is not safe to walk on projects at least 0.50 m above the roof surface.
- For other rooflights that are not safe to walk on, such as plastic translucent sheets, the risk assessment must decide which measures are needed within the 2-metre zone, for example guard rails, covers or personal fall protection equipment (no. 7.1 (4)).
Pitched roofs: preventing slipping
On inclined surfaces, the risk of slipping off is added to that of falling over the edge. The requirements for construction sites are set out in ASR A2.1 no. 8.1 and in Section 8 DGUV Vorschrift 38:
Inclined surfaces with a risk of slipping off
RequirementWork only after measures against slipping have been taken
BasisASR A2.1 no. 8.1 (1), Section 8 (4) DGUV Vorschrift 38
More than 22.5° up to 60°
RequirementHeight difference between the workplace or traffic route and the installation for catching employees who slip no more than 5.00 m
BasisASR A2.1 no. 8.1 (3)
More than 45°
RequirementCreate special workplaces, for example horizontal standing areas at least 0.50 m wide, roof ladders or roofers' chairs
BasisASR A2.1 no. 8.1 (2), Section 8 (5) DGUV Vorschrift 38
More than 60°
RequirementThe edge to a surface this steep is itself regarded as a fall edge
BasisASR A2.1 no. 3.2
Weather belongs in every assessment: wind, wet, ice and snow change slip resistance and balance (ASR A2.1 no. 4.1 (1)). Temporary construction work outdoors on ladders may not be started or continued if, for example due to strong or gusty wind, icing or slippery snow, there is a possibility that employees may fall (Section 8 (7) DGUV Vorschrift 38).
Anchor devices: planning, documentation and inspection
Personal fall protection equipment only protects if it is attached to a suitable anchor device. The requirements for anchor devices are governed by DIN EN 795. A legal distinction is made: temporary anchor devices that are removed again after use are regarded as personal protective equipment. Anchor devices that are permanently connected to the structure and remain there are construction products; for these, DIN EN 17235 describes performance characteristics and test methods (DGUV Information 201-056).
- Responsibility: the operator must ensure the functional safety of the anchor devices throughout their service life.
- Inspection interval: DGUV Information 201-056 recommends that no more than 12 months pass between inspections and maintenance of permanent anchor devices. The manufacturer's specifications, ambient conditions and frequency of use are decisive.
- Inspector: the inspection is carried out by a person qualified for it, depending on the system with training or authorisation from the manufacturer. Anchor devices certified exclusively to EN 795 and installed up to and including 2015 must be inspected by an expert for personal fall protection equipment under DGUV Grundsatz 312-906.
- Scope: first it is checked whether the installation documentation is complete. This is followed by a visual and functional check according to the manufacturer's specifications, among other things for damage, deformation, corrosion and correct installation, with a manual shake test and, for cable systems, a check of the pretension.
- Existing systems without documentation: if the manufacturer or the type of fastening is not known, the inspection cannot be continued according to the DGUV Information. If both are known, at least 30 per cent of the anchor devices including their fastening are checked; if one is faulty, all of them.
- Documentation: the actual condition is recorded, the safe condition for use is confirmed and the report is handed to the operator. Photographic documentation is recommended.
- Edge protection and guard rails: for edge protection systems and guarding, the DGUV Information recommends a check at intervals of no more than 24 months.
Construction work on the roof: DGUV Vorschrift 38 and contractors
The accident prevention regulation “Bauarbeiten” (construction work, DGUV Vorschrift 38) does not only apply to new buildings. Construction work is work for the erection, assembly, maintenance, alteration, dismantling and removal of structures; this also includes repair, cleaning and servicing work (Section 2 (1)). The regulation is issued by the individual accident insurance institutions; the version of your Berufsgenossenschaft is decisive. For work on the roof, these points are particularly important:
- Management and supervision: construction work is managed by superiors who are authorised to give instructions and have the necessary expertise, and is supervised by supervisors who monitor that the work is carried out safely (Section 3 (1) and (2)).
- Falls: Section 9 contains the same thresholds as ASR A2.1 and the same order of priority of protective devices, fall arrest installations and personal fall protection equipment. The suitable anchor devices are defined in the individual case by the superior who is authorised to give instructions and has the necessary expertise (Section 9 (4)).
- Ladders: portable ladders may only be used as a workplace up to a standing height of 2.00 m, and above that up to 5.00 m only for temporary work, i.e. no more than two hours per shift. Access to workplaces must as a rule be provided by stairs or walkways (Section 8 (7), Section 2 (3)).
- Written instruction: for assembly, dismantling, demolition and deconstruction work with special safety requirements, a written instruction must be available on the construction site (Section 4).
As the client you remain under an obligation even when a contractor climbs onto your roof: inform them about surfaces that are not safe to walk on, access points, existing protection and its inspection status, and coordinate the work. For larger construction projects, the Construction Site Ordinance (Baustellenverordnung) also applies. The document it provides for later work on the structure (Section 3 (2) no. 3 BaustellV) is the place to record how the roof can be maintained safely later on.
Rescue concept and checklist before roof access
Anyone working with personal fall protection equipment needs a plan for the case that someone is hanging in the harness. Employees must be instructed in carrying out the necessary rescue measures (ASR A2.1 no. 4.2, Section 9 (4) DGUV Vorschrift 38). According to DGUV Information 201-056, the company carrying out the work must ensure rescue on its own responsibility: with a workplace-specific rescue concept, suitable rescue equipment and enough personnel on site. Instruction with practical exercises is repeated at least every 12 months. What belongs in a rescue concept is described in the guide “Fall protection equipment”.
- All work for which the roof is accessed recorded, with frequency and companies involved
- Fall edges, fall heights and surfaces that are not safe to walk on documented in a roof plan
- Access to the roof safe and locked against unauthorised entry, marking affixed
- Protective measures defined according to the order of priority: guarding, fall arrest installation, only then personal fall protection equipment
- Danger zone up to 2.0 m from the fall edge demarcated and marked where there is no guarding
- Dome rooflights and continuous rooflights secured against falling through
- Anchor devices with layout plan, installation documentation and current inspection report
- Personal fall protection equipment inspected, employees instructed with practical exercises
- Rescue concept prepared, rescue equipment on site, second person planned
- Weather assessed before work starts; no work in wind, wet, ice or snow
- Contractors briefed, work coordinated and released
Free templates for this guide
As PDF and Excel, free – to use in your own company.
- Work permits
Permit to work at height and on roofs – template (PDF)
PDFFree download - Safety instruction
Fall protection equipment briefing template with knowledge check (PDF)
PDFFree download - Operating instructions
Operating instructions for fall protection PPE – template (PDF) with sample text
PDF + WordFree download - Testing duties
Fall protection PPE inspection: checklist and inspection record (PDF & Excel) for the competent person
PDF + Word + ExcelFree download
Frequently asked questions
From what height is fall protection mandatory on the roof?
Under ASR A2.1, a fall hazard exists at a fall height of more than 1.0 m; protective measures must then be taken according to the order of priority. In construction work, fall protection must be in place at workplaces at a fall height of more than 2.00 m, at traffic routes, exposed stairs and wall openings at more than 1.00 m and at or above water regardless of height (ASR A2.1 no. 8.2, Section 9 DGUV Vorschrift 38).
Is it enough on a flat roof to keep two metres away from the edge?
Workplaces and traffic routes more than 2.0 m from the fall edge are outside the danger zone. However, the danger zone must be secured against unauthorised access by suitable measures such as chains or ropes and clearly visible marking (ASR A2.1 no. 5.4). Dome rooflights and other surfaces that are not safe to walk on also form fall edges to which the distance applies.
How often do anchor points on the roof have to be inspected?
The manufacturer's specifications are decisive. For permanent anchor devices, DGUV Information 201-056 recommends no more than 12 months between inspections and maintenance; a corrosive environment or frequent use may require shorter intervals. The personal fall protection equipment itself is inspected as required, but at least every 12 months, by an expert.
May dome rooflights be walked on?
No, as long as it has not been proven that they are safe to walk on. Under ASR A2.1 no. 3.11, dome rooflights and continuous rooflights are among the components that may not be safe to walk on. They must be secured against falling through by guarding, covers or nets or grids underneath; in existing buildings, barriers or covers are needed within 2.0 m unless the upstand projects at least 0.50 m above the roof surface (no. 7.1 (3)).
Who is responsible when a contractor works on the roof?
Both. The contractor is responsible as employer for its employees: risk assessment, instruction, PPE and rescue. The operator of the building must ensure the functional safety of the existing protection and provide information about hazards such as surfaces that are not safe to walk on. Where several employers work at one location, they must cooperate and coordinate (Section 8 ArbSchG).
This guide gives a general overview of German occupational safety law and does not replace legal advice. The regulations in force and the rules of the statutory accident insurance institutions are authoritative.
Organise occupational safety digitally
With the occupational safety software AMS Go you handle risk assessments, safety instructions, inspections and more in one system – mobile and with AI support.
Newsletter
Occupational safety, straight to your inbox
New templates, guides and changes to regulations – free from AMS Go. The newsletter is in German. You can unsubscribe at any time via the link in every email.
More guides
- Testing duties
Fall protection equipment in Germany: selection, instruction and annual inspection
7 minRead - Testing duties
Scaffold inspection in Germany: who inspects scaffolds, when and how under TRBS 2121
6 minRead - Safety instruction
Mobile elevating work platforms in Germany: training, authorisation and inspection
6 minRead - Testing duties
Ladder inspection in Germany: inspecting and using ladders and steps safely
7 minRead - Organisation
Construction site health and safety coordinator and plan in Germany: client duties, prior notice and content